Warranty 10 Years
IP rating IPX1
TPR Supplied
Cylinder Recovery Times (theorectical)
Based on a thermostat temp. setting of 60 °C and an incoming water temp. of 15 °C.
• 135 L = 3 hrs 56 mins (2 kW), 2 hrs 37 mins (3 kW)
• 180 L = 5 hrs 15 mins (2 kW), 3 hrs 30 mins (3 kW)
• 250 L = 7 hrs 17 mins (2 kW), 4 hrs 51 mins (3 kW)
• 250 L = 3 hrs 39 mins (2 x 2 kW), 2 hrs 25 mins (2 x 3 kW)
•300 L = 8 hrs 45 mins (2 kW), 5 hrs 50 mins (3 kW)
• 300 L = 4 hrs 22 mins (2 x 2 kW), 2 hrs 55 mins (2 x 3 kW)
Anode
Not required
Connections
Hot and cold water connections ¾ " (20 mm)
Construction
Inner cylinder: High grade copper Outer casing
Element
Incoloy 825 alloy sheath element positioned at the bottom of the tank.
Maximum working pressure
850 kPa
Pressure testing
To 15 Bar
Thermal insulation
CFC-free polyurethane foam, compliant with MEPS standard
Thermostat
Robert Shaw 30 A contact thermostat, manually resettable at 85 °C. Thermostat can be upgraded to an auto-reset thermostat for solar and hot water heat pump applications.
TPR valve
Rating of TPR supplied with cylinder— factory set to 850 kPa and 90 °C.
Compliance
No cylinder wrap required. All Rinnai cylinders meet the NZ Minimum Energy Performance Standard (MEPS).